100 MM THK SLAB ON GRADE COMPACTED SUBGRADE L 100 100MM BASE COURSE 6MIL PE VAPOR BARRIER 2.87m 5.65m H 4.26m W C1/F1 C1/F1 TYPICAL PLAN C1/F1 FOOTING SCHEDULE WF 3.00m 100MM SLAB ON GRADE Ø10 @ 400MM B.W. WF WF 3.43m FOOTING REINFORCEMENT (SEE SCHED) L D H REINFORCEMENT GRADE 60 F1 0.9 0.90 0.30 1.20 6 - 12 MMØ BW. SQUARE FOOTING F2 0.9 2.30 0.30 0.80 6- 12 MMØ BW. 15- 12 MMØ BW. RECTANGULAR FOOTING MARK WF D C1/F1 W REMARKS 100MM COMPACTED BASE COURSE W W WF SECTION FOOTING DETAIL NTS C1/F1 WF C1/F1 WF 3.28m WF WF 3.50m WF C1/F1 WF COLUMN SCHEDULE NOTE: MAIN REINFORCEMENT, ASTM GRADE 60 LATERAL TIES, ASTM GRADE 40 WF C1/F1 C1 1.30m C2 C1/F1 LEVEL C2/F2 1.00m C1/F1 0.70m FDN-ROOF BEAM 1.65m C2/F2 C2/F2 WF 1.30m FDN-ROOF BEAM 0.95m 0.20M WF C1/F1 3.95m C1/F1 Use 4-pcs. 12mmØ 4.05m 0.30M 0.70m FOUNDATION PLAN SCALE ROOF BEAM 1:50MTS SIZES 200X300 VERT. REINF. TIES REG. NO.: PROJECT TITLE : OWNER : TIN NO.: 200X300 6 - D12 4 - D12 4 SET,D10 @ 100 REST 200 1 SET,D10 @ 100 REST 200 DESIGN BY SHEET CONTENTS REVISIONS ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE BY CONTRACTOR. ALL DISCREPANCIES ARE TO BE IMMEDIATELY REPORTED TO ARCHITECTS & PROJECT MANAGERS. DRAWN BY NO: 7 P.T.R. ENGINEER CAD BY PROPOSED THREE BEDROOM RESIDENTIAL UNIT AS SHOWN ISSUED ON: ISSUED AT: CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT OF WORKS. ADDRESS : ADDRESS : THIS DRAWING, ACTING AS INSTRUMENT OF SERVICE, IS THE PROPERTY OF RECIO+CASAS,INC.. & CANNOT BE PRODUCED WITHOUT THEIR WRITTEN CONSENT. DATE DRAWN DATE PRINTED 6 5 4 CHECKED BY SCALE AS SHOWN - REPUBLIC ACT No. 545 3 2 1 DESCRIPTION SHEET NO: DATE: S 1 2