EVB1-HP - BRUSA Elektronik AG

advertisement
EVB1-HP - High Power HV - Battery
Enormous capability up to 240 kW(discharge)
Cutting-Edge Technology
• CAN-Bus controlled
• Integrated charger control (NLG5)
• Simply and fast installation / commissioning
• Compact and lightweight design
Safety first
• Integrated battery-management-system (BMS)
• Very high performance and energy density
(1,66 kW/kg and 110 Wh/kg)
• Fast measurement and monitoring of all cellvoltages / temperatures
• Watercooled for best Performance
• Automatic derating at overtemperature
• Parallel connection of several EVB1 possible
• Integrated fuse
• For automotive and industrial applications in
high-performance range (Mid-size cars, sports
cars, racing, hybrids, trucks, buses, boats etc.)
• Ah counter with DoD-management
• Integrated Loading device with short-circuit
detection
www.brusa.biz
• More than 500.000 km field testing with own
prototypes
BOTTOM
Dimensions EVB1-350-40-HP
BOTTOM
Dimensions EVB1-400-40-HP
• Automatic cell-Balancing (passive)
BRUSA Elektronik AG
Neudorf 14
CH-9466 Sennwald
+41 81 758 19 00
info@brusa.biz
Specifications EVB1-HP
Electrical data
EVB1-400-40-HP
EVB1-350-40-HP
1P108S
1P96S
---
Number of cells
108
96
---
Capacity (per cell) (charge at 0.2 C, 25 °C / discharge at 0.2 C, 25 °C)
40
40
Ah
16
14
kWh
Battery configuration
Energy content (charge at 0.2 C, 25 °C / discharge at 0.2 C, 25 °C)
Technology
Li-Ion
400
350
V
Max. voltage
448
400
V
Min. voltage
324
290
V
320 (128)
320 (112)
A(kW)
600 (240)
600 (210)
A(kW)
Max. charging current
120 (48)
120 (42)
A(kW)
Internal resistance at 25°C
130-150
120-140
mΩ
600
600
A
CAN-Bus (500k/1Mbit)
CAN-Bus (500k/1Mbit)
--uA
Discharge current cont.
Discharge current peak (10s, SoC > 50%)
Internal fuse protection
Control
Power consumption offline / Standby (per Cell)
40
40
BMS-Power consumption at internal fan power = 100% (Kl. 30 = 12V)
3.6
3.6
A
up to 4000
up to 4000
---
Life expectancy to 80% cap. (80% DoD or 3.4V - 4.1V at 25°C)
Mechanical data / Cooling system
EVB1-400-40-HPEVB1-350-40-HP
Coolant quantity in device
Recommended coolant temperature at the inlet
Min. coolant temperature at the inlet
Max. coolant temperature at the inlet
Temperature range charge
Temperature range discharge
Coolant medium pressure loss @ 6l/min, Tcoolant = 25°C (water/glycol = 50/50)
Maximum pressure of coolant medium
System weight (without coolant medium)
IP-protetion
EVB1-400-40HP Discharge with 600 A (240kW)
approx. 450
approx. 400
ml
+5 to +20
+5 to +20
°C
0
0
°C
< +40
< +40
°C
0 to +45
0 to +45
°C
-10 to +55
-10 to +55
°C
66
60
mbar
1.0
1.0
bar
approx. 145
approx. 130
kg
IP65
Performance of water cooler
BRUSA / 01.2016 / EVB1-HP
Li-Ion---
Nominal voltage
approx. 1000
IP65--approx. 900
W
Safety concept
EVB1-400-40HP Discharge with 320 A (128 kW)
Optional we recommend using the following products:
•
•
www.brusa.biz
Isolation guard ISO1-500-50
PDU254 with Interlock generator
BRUSA Elektronik AG
Neudorf 14
CH-9466 Sennwald
+41 81 758 19 00
info@brusa.biz