Bartco Lighting Specs

advertisement
VISIONS BROUGHT TO LIGHT™
bartcoLIGHTING.com
Type:
bartcoLIGHTING.com | t.714.230.3200 | f.714.230.3222
RSL5
low profile T5 expandable/retractable fluorescent fixture - field adjustable to 2', 3' or 4' nominal
lengths
Fully assembled housing is formed and welded,
20 ga. steel, chemically treated to resist
corrosion and enhance paint adhesion
T5
Standard finish is high reflectance white powder
coat, applied post production
Adjustable for one T5 14W, 21W and 28W linear
fluorescent lamp
Standard ballast is specification grade 120V277V program start (consult factory for other
voltage options)
Dimming option available (consult factory for
availability and system compatibility)
Knock-outs accept standard electrical fittings by
others (consult factory for other locations)
Surface mount
Rotational locking lamp holders, patent no.
7,097,327 B-1
UL and ULC listed for dry and damp locations
IBEW manufactured and labeled
Made in the U.S.A.
patent pending
Cover Top
Cover Top
14W
21W
28W
Fixture adjustable to 14W, 21W, 28W T5 lengths
*Consult factory for Dimming options. *Consult factory for custom finishes.
Profile
Top View
14W
22-1/2”
Slide
to extend
21W
2-7/8”
34-5/16”
2”
Slide
to extend
28W
1-5/8”
46-1/16”
©2011 Bartco Lighting, Inc. These products are protected by patents and patents pending. Unauthorized use or reproduction of illustrations, photographs or text is prohibited. Bartco Lighting
reserves the right to discontinue products or to change the technical and/or design specifications at any time. The SLIDE-A-LIGHT™ and icon are trademarks of Bartco Lighting, Inc.
01.2011
pg.01
Type:
bartcoLIGHTING.com | t.714.230.3200 | f.714.230.3222
bartcoLIGHTING.com | t.714.230.3200 | f.714.230.3222
BT6100 | ACCESSORIES
BT6100
fixture
surface mount linear T6 fluorescent
Fully assembled housing is formed and welded,
20 ga. steel, chemically treated to resist corrosion and enhance paint adhesion
T6
Standard finish is Fluoroscape White powder
coat, applied post production
LENSES |
Available for one T6 20", 34", 40", 50" and 60"
nominal length linear fluorescent lamp
U6LNP
Round Profile
U6LNCF
Round Profile
U6LNP-SQ
Square Profile
U6LNCF-SQ Square Profile
Electronic 120V or 277V ballast is pre-wired to
the lamp holders
Integral emergency ballast available (60” nondimming only, 1000 lumens, consult factory)
Clear fine prismatic acrylic lens with mounting clips (sold by the foot)
Frosted acrylic lens with mounting clips (sold by the foot)
Clear fine prismatic acrylic lens with mounting clips (sold by the foot)
Frosted acrylic lens with mounting clips (sold by the foot)
___ft.
___ft.
___ft.
___ft.
10% Dimming ballast available (requires
interface, consult factory for availability and
system compatibility)
Knock-outs on back accept standard electrical
fittings by others (consult factory for other
locations)
Accessory reflectors and lens available
REFLECTORS | 20 ga. steel with white powder coat interior or .020" aluminum in specular (TR=95%) or semi-specular (TR=94%) interior finish
4"
Non-dimming fixtures are UL/ULC listed for
damp location and through wiring
Dimming fixtures are UL/ULC listed for dry
location and through wiring
2 12"
IBEW manufactured and labeled
SPECIFICATIONS / ORDER FORMAT
model no.
reflector style
nominal length
interior finish
exterior finish
6100
-R1 - symmetrical
-20
/WH - white
/FW - Fluoroscape white
-R2 - asymmetrical
-34
/A1 - specular
/CU - custom finish (consult factory)
-40
/A2 - semi-specular
Made in the U.S.A.
2 15 16"
-50
-60
2 12"
Watts
Voltage
Finish
Mount
Ballast
W
BT6100 +
+
Section 1
+
Section 2
17W: 19-13/16”
U: 120V-277V
27W: 33-9/16”
CF: consult factory for
specialize voltage
*30W: 39-1/2”
+
Section 3
DIM: Dimming
(consult factory)
ND: Non-Dimming
+
Section 4
SM: surface mount
DIMMING INTERFACE | allows simple integration with common dimming control methods, 120V-277V input, surface mount aluminum enclosure
Section 5
(see interface cutsheet for complete specifications)
BT-AS-1
BT-AS-3
FW: fluoroscape white
CF: consult factory for
custom color
Astara PWM interface, single circuit, 25 fixtures max.
Astara PWM interface, three circuit, 60 fixtures max. (3x20 fixtures)
EB: emergency ballast
(consult factory)
*38W: 49-5/16”
*45W: 59-3/16"
CF: consult factory for
ballast option
*Wattage rating for non-dimming ballast. When using dimming ballast, add one watt.
Profile
Side View
2-7/16”
1-7/8”
©2011 Bartco Lighting, Inc. These products are protected by patents and patents pending. Unauthorized use or reproduction of illustrations, photographs or text is prohibited. Bartco Lighting
reserves the right to discontinue products or to change the technical and/or design specifications at any time. The BT6™ logo and icon are trademarks of Bartco Lighting, Inc.
01.2011
pg.01
©2011 Bartco Lighting, Inc. These products are protected by patents and patents pending. Unauthorized use or reproduction of illustrations, photographs or text is prohibited. Bartco Lighting
reserves the right to discontinue products or to change the technical and/or design specifications at any time. The BT6™ logo and icon are trademarks of Bartco Lighting, Inc.
01.2011
pg.02
VISIONS BROUGHT TO LIGHT™
Type:
bartcoLIGHTING.com | t.714.230.3200 | f.714.230.3222
IPR5S
Fully assembled housing is formed and welded,
20 ga. steel, chemically treated to resist corrosion and enhance paint adhesion
T5
square top, linear T5 fluorescent
fixture with lens
Model variations offered for surface, cable suspended and pendant mount applications
Available in standard white, black, silver, platinum, bronze and primer powder coat, applied
post production (consult factory for custom
finishes)
Includes frosted or linear prismatic acrylic lens
Available for T5 14W, 21W, 28W, 35W and high
output 24W, 39W, 54W, 80W linear fluorescent
lamps in single and some tandem lengths
Standard ballast is specification grade 120V277V program start (consult factory for other
voltage options)
Dimming, emergency battery backup and specialized ballast factor options available (consult
factory for availability and system compatibility
Knock-outs on back accept standard electrical
fittings by others (consult factory for other
locations)
Rotational locking lamp holders
UL and C-UL listed for dry and damp locations
IBEW manufactured and labeled
Made in the U.S.A.
Watts
Voltage
Lens
Ballast
Finish
Mount
W
IPR5S +
+
Section 1
+
Section 2
+
Section 3*
+
Section 4
+
Section 5
Section 6
14W: 22-1/2”
U: 120V-277V
[Non-Dimming]
[Emergency]
F: frosted
SM: surface mount
WH: white
21W: 34-5/16”
347: 347V
PRS: program rapid start
I28: Iota ISL-28
P: linear prismatic
BL: black
28W: 46-1/16”
CF: consult factory
for specialize voltage
[Dimming]
I54: Iota ISL-54
CM48: cable mount
48” cable length
MKX: Advance Mark 10
I540: Iota ISL-540-35W
PT: platinum
24W: HO - 22-1/2”
VII: Advance Mark 7
L28: Iota ISL-28
CM96: cable mount
96” cable length
39W: HO - 34-5/16”
H300: Lutron Hi-Lume 3D
L50: Bodine LP500
PR: primer
54W: HO - 46-1/16”
ESYS: Lutron EcoSystem
L55: Bodine LP5500
PM18: pendant mount
18” stem length
80W: HO - 57-15/16”
ECO: Lutron Eco-10
L60: Bodine LP600
EHD: Lutron EcoSystem H
L60S: Bodine LP600STU
35W: 57-15/16”
DALI: Dali T5
PHO: Sylvania Helios
TEN: SuperDim
PM24: pendant mount
24” stem length
SL: silver
BZ: bronze
CF: consult factory for
custom color
PM30: pendant mount
30” stem length
CF: consult factory for
custom length
*Not all ballasts work with all lamps. Consult factory for details.
Profile
Top View
3”
Side View
1-1/2”
1-7/16”
©2011 Bartco Lighting, Inc. These products are protected by patents and patents pending. Unauthorized use or reproduction of illustrations, photographs or text is prohibited. Bartco Lighting
reserves the right to discontinue products or to change the technical and/or design specifications at any time. The Essence Collection™ logo and icon are trademarks of Bartco Lighting, Inc.
01.2011
pg.01
Type:
bartcoLIGHTING.com | t.714.230.3200 | f.714.230.3222
eco-8
ECO 8
retrofit linear LED line voltage lamp
LED
operates with or without existing ballast
PERFORMANCE
LED tubes are arranged in standard linear T8
fluorescent sizes
Components can install as direct replacements
for linear fluorescent lamp
Construction: extruded aluminum body/heat
sink
LED lumen output: 100 Lumens/350 mA
LED beam spread: 180°
Linear lamp operating temperature: 50°C @
25°C ambient
Listing: ETL, UL
Base - medium Bi Pin
POWER SUPPLY
Direct line voltage LED lamp does NOT need an
external driver
Operating voltage 100V - 300V
Can be used with a variety of Bartco
luminaires
*Fixture Sold Separately
Option 1: Retrofit Luminaire - Ballast
Option 2: Retrofit Luminaire - Line Voltage
Step 1: Turn off main power before installation.
For safety, make sure main power source is switched off before attempting to install.
Step 1: Turn off main power before installation.
For safety, make sure main power source is switched off before attempting to install.
Step 2: Take out existing fluorescent lamp.
Step 2: Take out existing fluorescent lamp and bypass the electronic ballast.
Step 3: Replace with Retrofit ECO8 LED lamp
Step 3: Reconnect one end of the socket to power source.
Please refer to below wiring diagram.
Adhere Label “AC Input” supplied in the package to the AC input end of the retrofit luminaire.
Step4: Switch main power on to light up.
Step 4: Drop into the luminaire.
Note: The end labeled “AC Input” is AC Input end. Wrong connection will burn it out.
Step5: Switch main power on to light up.
Wiring Diagram (Electronic Ballast)
Before
ECO8 +
°K
Color
Temp
Overall
Length
+
Section 1
+
Section 2
Section 3
After
2: 10W, 2' Bi Pin - 23.2” @ 550 lm
WW: Warm White
3K: 3,000 +/- 100º
3: 15W, 3' Bi Pin - 35.2” @ 850 lm
NW: Neutral White
4K: 4,000 +/- 100º
4: 20W, 4' Bi Pin - 47.2” @ 1100 lm
CF: consult factory for other sizes
CF: for other ºK,
consult factory
Specification order example: ECO8 + 2 + WW + 3K
©2011 Bartco Lighting, Inc. These products are protected by patents and patents pending. Unauthorized use or reproduction of illustrations, photographs or text is prohibited. Bartco Lighting
reserves the right to discontinue products or to change the technical and/or design specifications at any time.
01.2011
pg.01
Download